Multi Cable Corporation
(860) 589-9035

Parallel Pair Thermocouple Cable: Unshielded - PTFE Tape Insulated & Jacketed - 1900 Series

Parallel Pair Thermocouple Cable: Unshielded - PTFE Tape Insulated & Jacketed - 1900 Series
  • Made to order
  • Cut to length
  • Stocking program available
Download Spec Sheet

Product Description

  • Solid or stranded thermocouple wire per ASTM E230 & ANSI MC 96.1
  • Insulated with two layers of fused fluoropolymer PTFE tape 
  • Conductors color coded per ANSI MC 96.1
  • International color codes available

Temperature Rating

  • -200ºC to 260ºC

Limits of Error

  • Guaranteed conformance to ASTM E230 and ANSI MC 96.1
  • Tighter tolerances than industry standards on alloy selection guarantee high system accuracy
Calibration Temperature Range Standard Limits of Error Special Limits of Error*
BX (Cu vs. Cu) 0º to 100ºC +/- 4.2ºC NA
BX (PCLW vs. Cu) 0º to 200ºC +/- 3.7ºC NA
E 0º to 870ºC +/- 1.7ºC or 0.5% +/- 1.0ºC or 0.4%
EX 0º to 200ºC +/- 1.7ºC +/- 1.0ºC
J 0º to 760ºC +/- 2.2ºC or 0.75% +/- 1.1ºC or 0.4%
K or N 0º to 1260ºC +/- 2.2ºC or 0.75% +/- 1.1ºC or 0.4%
KX or NX 0º to 200ºC +/- 2.2ºC +/-1.1ºC
RX or SX 0º to 200ºC +/- 5.0ºC NA
T 0º to 370ºC +/- 1.0ºC or 0.75% +/- 0.5ºC to 0.4%
TX 0º to 100ºC +/- 1.0ºC +/- 0.5ºC

*When specifying special limits of error, use double ANSI letter designation, i.e. KK, JJX, etc.

Applications

  • Aerospace
  • Power Generation
  • Laboratories
  • Petrochemical Plants
  • Cryogenic Applications
  • FDA Approved Applications
  • Composites

Approvals

  • RoHS Compliant

Save Time & Money with Custom Cable

Multi/Cable products are designed & manufactured to suit your specific applications.

Call (860) 589-9035 or Request a Quote